;-----------------------------------------------------------------------------\ ; ; ; Adapted for EN425 ; ; ; ; ; ADCP Command File for use with VmDas software. ; ; ADCP type: 75 Khz Ocean Surveyor ; Setup name: default ; Setup type: Low resolution, long range profile(narrowband) ; ; NOTE: Any line beginning with a semicolon in the first ; column is treated as a comment and is ignored by ; the VmDas software. ; ; NOTE: This file is best viewed with a fixed-point font (eg. courier). ;----------------------------------------------------------------------------/ ; Restore factory default settings in the ADCP cr1 ; set the data collection baud rate to 115200 bps, ; no parity, one stop bit, 8 data bits ; NOTE: VmDas sends baud rate change command after all other commands in ; this file, so that it is not made permanent by a CK command. cb811 ; Set for narrowband profile mode, single-ping ensembles, ; one-hundred 8 meter bins, 8 meter blanking distance WP0 NP00001 NS800 NF0800 NN100 ; Disable single-ping bottom track use BP0, Enable bottom track use BP1 ; Set maximum bottom search depth to 1200 meters BP001 BX12000 ; output velocity, correlation, echo intensity, percent good ND111100000 ; Two seconds between bottom and water pings TP000200 ; Four seconds between ensembles ; Since VmDas uses manual pinging, TE is ignored by the ADCP. ; You must set the time between ensemble in the VmDas Communication options TE00000400 ; Set to calculate speed-of-sound, no depth sensor, ; external synchro heading sensor, use internal ; transducer temperature sensor EZ1020001 ; Output beam data (rotations are done in software) EX00000 ; Set transducer depth to 5meters ED00050 ; External Trigger Output Off CX0,0 ; save this setup to non-volatile memory in the ADCP CK