;-----------------------------------------------------------------------------\ ; ; Changed for use with Tim Duda's 300KHZ unit on EN425 ; ; ;ADCP Command File for use with VmDas software. ; ; ADCP type: 75 Khz Ocean Surveyor ; Setup name: default ; Setup type: High resolution, short range profile(broadband) ; ; NOTE: Any line beginning with a semicolon in the first ; column is treated as a comment and is ignored by ; the VmDas software. ; ; NOTE: This file is best viewed with a fixed-point font (eg. courier). ;----------------------------------------------------------------------------/ ; Restore factory default settings in the ADCP cr1 ; set the data collection baud rate to 115200 bps, ; no parity, one stop bit, 8 data bits ; NOTE: VmDas sends baud rate change command after all other commands in ; this file, so that it is not made permanent by a CK command. cb811 ; Set for broadband profile mode, single-ping ensembles, ; 128 - 4 meter bins, 4 meter blanking distance, 390 mm/s ambiguity vel ; NP0 Was an OS75 command, not used for BB 300khz, we think... WP00001 WS0400 WF0400 WN064 WV390 ; Enable single-ping bottom track, ; Set maximum bottom search depth to 500 meters BP001 BX5000 ; output velocity, correlation, echo intensity, percent good WD111100000 ; one seconds between bottom and water pings TP000100 ; Four seconds between ensembles ; Since VmDas uses manual pinging, TE is ignored by the ADCP. ; You must set the time between ensemble in the VmDas Communication options TE00000400 ; Set to calculate speed-of-sound, no depth sensor, ; external synchro heading sensor, use internal ; transducer temperature sensor EZ1020001 ; Output beam data (rotations are done in software) ; One indicates use 3-beam solution (EX00010) EX00010 ; Set transducer depth to 5meters ED00050 ; External Trigger Output Off ; CX0,0 ; save this setup to non-volatile memory in the ADCP CK